Skip to content
TranslucentTB.io

TranslucentTB error 0x800401E3: Operation unavailable

TranslucentTB error 0x800401E3 shows "Operation unavailable" as the app starts with Windows. The code is a standard Windows one, MK_E_UNAVAILABLE: the app looked for a running object to connect to and it was not there yet.

Checked against TranslucentTB 2026.2. Last updated .

Why it appears at sign-in

At logon TranslucentTB can start before the part of Explorer it needs has registered itself. The connection attempt fails and the app treats the failure as fatal.

Started by hand a little later, the same install usually works. Error 0x80070102, the wait operation timed out, is the other message this early start produces.

The fix that is on its way

A change that stops this timeout from being fatal was merged into the project's development branch on 5 November 2026 (pull request #1359). It is not in version 2026.2. It should arrive with the next release, the same one that restores support for the newest Windows 11 builds.

What to try now

  1. Close the dialog and launch TranslucentTB from the Start menu.
  2. If the error repeats, restart Windows Explorer from Task Manager and try once more.
  3. If it happens at every boot, untick Open at boot and start the app yourself after sign-in until the update ships.

One user's workaround

In issue #1258, one person reported that ticking "Disable fullscreen optimizations" on the Compatibility tab of the executable's properties stopped the error for them. Nobody else has confirmed it and the developer has not endorsed it. It is harmless to try on the portable build, where you can reach the exe's properties.

Sources: issue #1258, pull request #1359.

Related pages

See everything under Fixes.

Get the latest TranslucentTB